  the a bc 180 series of ultra low profile open frame power supplies feature a wide universal ac input range of 80 C 264 vac, offering up to 180 w of output power with 13 cfm, or up to 120 w with convection cooling in a compact footprint, with a variety of isolated single output voltages. t he high efficiency and high power density of the abc family ensures minimal power loss in end - use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmen tally - friendly end products. these power supplies a re ideal for broad range of telecom, d atacom, industrial equipment and other applications. ? 4 x 2 x 0.75 inches form factor ? 180 watts with forced air cooling ? efficiencies up to 9 2% ? - 40 to 70c degree o perating temperature ? 12 v / 0.5 a fan output, thermal shut - down feature ? 3.37 m illion hours, telcordia - sr332 - issue 3 mtbf ? standby power < 0.5w ? instrumentation ? lighting ? industrial applications ? applied computing ? renewable energy ? test and measurement ? robotics ? wireless communication
abc180 series 2 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab abc180 - 1t12l screw terminal 12 v 9.3 7 a 10 a 15 a 0.0 a 2 % abc180 - 1012l molex connector abc1 80 - 1t15 l screw terminal 15 v 7.5 a 8 a 12 a 0.0 a 2 % abc180 - 1015l molex connector abc180 - 1t 24 l screw terminal 24 v 4.68 a 5 a 7.5 a 0.0 a 1% abc180 - 10 24 l molex connector abc180 - 1t 30 l screw terminal 30 v 3.75 a 4 a 6 a 0.0 a 1% abc180 - 10 30 l molex connector abc180 - 1t48l screw terminal 48 v 2.34 a 2.5 a 3.75 a 0.0 a 1% abc180 - 1048l molex connector abc180 - 1t 58 l screw terminal 58 v 1.94 a 2.07 a 3.1 a 0.0 a 1% abc180 - 1058l molex connector cover - 180 - xbc 2 metal cover kit accessory specifications are for nominal input voltage, 25c unless otherwise stated. input voltage universal ( derate from 100% at 100 vac to 7 7% at 8 0 vac) 80 - 264 vac / 390 vdc input frequency 47 - 63 hz input current 115 vac: 230 vac : 2.2 a max. 1.1 a max. no load power typical for abc180 - 1xxx typical for abc180 - 1xxx - pgpf < 0.5 w < 0.85 w inrush current 115 vac: 230 vac: 264 vac: 25 a 45 a 75 a leakage current typical (n.a. for class ii option - without input earth pin ) touch current 3 00 a < 1 00 a power factor 115 vac: 230 vac : > 0.95 0.90 switching frequency pfc pwm 70 to 130 k hz 50 to 80 k hz 1 ripple is peak to peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. 2 when used in cover kit, de - rate output power to 70 % under all operating conditions.
abc180 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab output power 3 with 13 cfm forced air cooling with natural convection cooling at 100 to 264 vac 180 w up to 120 w efficiency ( typical @ 230 vac full load ) 48 v, 58 v : 24 v, 30 v : 12 v, 15 v: 92 % 9 0 % 88 % hold - up time at 180 w: at 120 w: 10 ms 16 ms line regulation +/ - 0.5% load regulation +/ - 1% transient response 25% step load change, at 0.1 a/ s slew rate, 50% duty cycle, 50 hz = 4% recovery time < 5 ms voltage adjustment 4 +/ - 3% rise time typical 55 ms set point tolerance 5 +/ - 1% over current protection > 110% over voltage protection 110 to 140% short circuit protection hiccup mode operating temperature 6 startup guaranteed with spec . deviation - 40 to +70c - 40 to 0c storage temperature - 40 to +85c relative humidity non - condensing 5% to 95% altitude operating: non - operating: 16,000 ft. 40,000 ft. mtbf telcordia - sr332 - issue 3 3.37 million h ours conducted emissions en55032 - b, cispr22 - b, fcc part15 - b pass radiated emissions en 55032 a; with external core (king core k5b rc 25x12x15 - m in input cable) pass level b input current harmonics en 61000 - 3 - 2 class d voltage fluctuation and flicker en 61000 - 3 - 3 pass esd immunity en 61000 - 4 - 2 level 3, criterion a radiated field immunity en 61000 - 4 - 3 level 3, criterion a electrical fast transient immunity en 61000 - 4 - 4 level 3, criterion a surge immunity en 61000 - 4 - 5 level 3, criterion a conducted immunity en 61000 - 4 - 6 level 3, criterion a magnetic field immunity en 61000 - 4 - 8 level 3, criterion a voltage dips, interruptions en 61000 - 4 - 11 criterion a & b 3 combined output power of main output, fan supply shall not exceed max. power rating. 4 adjustment potentiometer is located on the smt side of the pcb. 5 fan supply output voltage tolerance including set point accuracy, line & load regulation is +/ - 10% and ripple & noise is less than 10%. 6 output ripple can be more than 10% of the output voltage.
abc180 series 4 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab isolation voltage input to output: ( f or ite applications) input to gnd: (not applicable for class ii option * ) 3 000 vac 1500 vac safety standard(s) approved to the latest edition of the following standards: csa/ul60950 - 1, en6095 0 - 1 and iec60950 - 1. class1 selv agency approvals nemko, ul, c - ul ce mark complies with lvd directive * class ii option means without input earth pin. ac input connector j1 pin 1 pin 2 pin 3 ac line not fitted ac neutral * molex: 26 - 60 - 4030 mating: 09 - 50 - 3031; pins: 08 - 50 - 0106 dc output connector j2 pin 1, 2, 3 pin 4. 5. 6 v 1 + ve v1 - ve option 1 (screw terminal): molex: 39357 series or equivalent option 2 (molex connector): molex: 26 - 60 - 4060 mating: 09 - 50 - 3061; pins: 08 - 50 - 0106 aux (fan) output j3 pin 1 pin 2 fan + ve fan - ve amp: 640456 - 2 mating: 640440 - 2 signal output 7 j4 pin 1 pin 2 pin 3 vs pgpf gdn amp :640456 - 3 mating: 640440 - 3 * fusing on neutral for ite model is optional. power good / ac fail signal specs weight approx. 200 g dimensions 101.6 x 50.8 x 19.05 mm (4 x 2 x 0.75 inches ) cooling 8 180 w with 13 cfm forced air cooling (refer to mechanical drawing) up to 120 w with natural convection cooling (refer to derating curve) 7 a ttl signal is available at pin 2 of j4 which goes high 100 - 500ms after output voltage reaches 90% of set value. it goes low a minimum of 1 ms before output falls below 90% of the set value, when input ac is switched off. 8 180 w with 13cfm forced air cooling and 120 w with natural convection cooling at 100 to 264 vac.
abc180 series 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab mechanical drawing C option 1 without pgpf mechanical drawing C option 2 without pgpf notes: in case the pcb is mounted in a metal enclosure, using metal hardware ensure the following: 1 stand off, used to mount pcb has od of 5.4 mm max. 2 screws, used to fix pcb on stand off, have head dia of 6.0 mm max. 3 washer, if used, to have dia of 6.5 mm max.
abc180 series 6 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab mechanical drawing C option 1 with pgpf mechanical drawing C option 2 with pgpf notes: in case the pcb is mounted in a metal enclosure, using metal hardware ensure the following: 1 stand off, used to mount pcb has od of 5.4 mm max. 2 screws, used to fix pcb on stand off, have head dia of 6.0 mm max. 3 washer, if used, to have dia of 6.5 mm max.
abc180 series 7 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2017 bel power solutions & protection bcd.00879_ab nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of COVER-180-XBC2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X